Circuit Breakers Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical

Circuit Breakers Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical

Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 20 (1″) spaces, 40 poles, 120/240 volt AC. Main breaker type BW at 10,000 AIC. Furnished with hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 – 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977.

Read More Main Breaker Load Center, 200 Amp

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Circuit Breakers Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical

120/240 volt AC, 10,000 AIC, wire size range #14-4. Type CL replacement breakers, classified as direct replacements by Underwriters Laboratories for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE_/Siemens loadcenters

Read More Two Pole Circuit Breaker, 40 Amp

Circuit Breakers Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical

Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1″) spaces, 8 poles, 120/240 V. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 – 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741.

Read More Main Lug Load Center, 125 Amp

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Circuit Breakers Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical

120/240 volt AC, 10,000 AIC, wire size range(1) #14-8, (2) #14-10. UL listed, meets UL 489. Replacement for Square D type QO breakers. Requires two 3/4-inch (19.1 mm) spaces.

Read More Circuit Breaker, 2 Pole 60 Amp

Circuit Breakers Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical

Single phase, 3 wire, insulated/bondable split neutral, 12 (1″) spaces, 24 poles, 120/240 Volts AC. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC,suitable for use as service equipment when not more than 6 main disconnecting means are provided and when not used as a lighting and appliance panelboard. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connectionsmay be used for equipment ground protectors in service entrance application. #6 – 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977

Read More 125 Amp Main Lug Indoor Load Center

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Circuit Breakers Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical

Circuit Breakers Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical

Single phase, 3 wire, insulated/bondable split neutral, 16 (1″) spaces, 24 poles, 120/240 volt. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #6 – 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977.

Read More Indoor Main Lug Load Center, 125 Amp

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels