– Factory installed 30 Amp & 20 Amp single pole circuit breakers – 30 Amp Receptacle – Color: Gray – 20 Amp GFI Duplex Receptacle – Type 3R Rain Tight Enclosed – Surface Mount -Unmetered – Rain tight cover design allows cord to be used when do

Read More RV Panel

Circuit Breakers Fuses & Load Centers Connecticut Electrical Lighting & Electrical Panels

Single phase, 3 wire. 2 pole, 120/240 Volts AC. 10,000 AIC. Includes No. ECB225R enclosure with factory installed No. BW2200 circuit breaker and ground lug. No. GBK5P ground bar and DS type hub sold separately. For use as main breaker or service disconnect, as service entrance equipment when used with ground bar. Electrostatic powder coat, baked urethane painted. #2 – 300 kcmil wire range. U.L. Listed.

Read More 200 Amp Circuit Breaker Enclosure

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Single phase, 2 pole, 2 wire, 240 Volts AC, non-metallic enclosure. Rated 1-1/2 HP at 120 Volts, 3 HP at 240 Volts with time delay fuses (uses Class H cartridge fuses, not included). For top and bottom entry and exit, with provision for Type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. Swing-up cover remains in place when in open position, and includes provision for padlocking. 10,000 amps RMS symmetrical interrupting rating. Suitable for use as service entrance equipment with ground bar. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. U.L. Listed file No. E5239.

Read More Fusible AC Disconnect Switch, 30 Amp

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Single phase, 3 wire, insulated/bondable split neutral, 30 (1″) spaces, 40 poles, 120/240 Volts AC. Has notch for No.BRHDK125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #1 – 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977.

Read More 200 Amp Main Lug Indoor Load Center

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Single phase, 3 wire, insulated/bondable split neutral, 16 (1″) spaces, 24 poles, 120/240 volt. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #6 – 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977.

Read More Indoor Main Lug Load Center, 125 Amp

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Welded sheet steel. Single phase, 3 wire, split neutral, 20 spaces, 20 circuits, 120/240 V. 22,000 AIR factory installed main breaker U.L. Listed for use ahead of QO and QOT 10,000 AIR branch breakers to permit their application systems with up to 22,000amps available fault current. QOM1 frame size. 3 mounting locations for ground bar, use bar No.PK15GTA sold separately. Shielded copper bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 – 1 AWG main wire. Gray baked-on enamel finish. U.L. Listed.

Read More Main Disconnect Breaker Box, 100 Amp

Circuit Breakers Fuses & Load Centers Electrical Lighting & Electrical Panels Your One Source

Circuit Breakers Fuses & Load Centers Electrical Lighting & Electrical Panels Your One Source

Welded sheet steel enclosure. Single phase, 3 wire, split neutral, 40 spaces, 40 circuits, 120/240 V. 10,000 AIR factory installed main breaker, QOM2 main frame size. 3 different mounting locations for ground bar, use No.PK23GTA bar sold separately. Rugged bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 – 250 kcmil main wire. Gray baked-on enamel finish. U.L. Listed.

Read More Homeline Load Center, 200 Amp

Circuit Breakers Fuses & Load Centers Electrical Lighting & Electrical Panels Your One Source

Single phase, 3 wire, solid neutral, 8 spaces, 16 circuits, 8 tandem breakers accepted, 120/240 Volts AC. 10,000 AIR. No. PK7GTA ground bar sold separately. Slot/square drive screws, 3 ground bar mounting locations. Straight in main design. Tangential main service knockouts. No provision for lock kits. #8 – #1 AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed.

Read More 100 Amp Main Lug Load Center

Circuit Breakers Fuses & Load Centers Electrical Lighting & Electrical Panels Your One Source

Single phase, 3 wire, insulated/bondable split neutral, 12 (1″) spaces, 24 poles, 120/240 Volts AC. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC,suitable for use as service equipment when not more than 6 main disconnecting means are provided and when not used as a lighting and appliance panelboard. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connectionsmay be used for equipment ground protectors in service entrance application. #6 – 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977

Read More 125 Amp Main Lug Indoor Load Center

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1″) spaces, 8 poles, 120/240 V. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 – 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741.

Read More Main Lug Load Center, 125 Amp

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels

Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 20 (1″) spaces, 40 poles, 120/240 volt AC. Main breaker type BW at 10,000 AIC. Furnished with hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 – 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977.

Read More Main Breaker Load Center, 200 Amp

Circuit Breakers Fuses & Load Centers Cutler-Hammer Electrical Lighting & Electrical Panels